sales@fluxtronics.co.in           +91-80-23193153

Single Phase Servo Stabilizer is a device which results in constant output voltage still there is certainly variance in input voltage when input voltage within for which it designed.Our products are reliable to a large extent as we provide a failure proof control circuit, highly protected with an Input and Output Low/high Voltage. We certainly have reached this position resulting from our technical strengths and vast experience in the field by manufacturing customized products as per client’s needs.

SALIENT FEATURES:
  • Reliable and trouble free operation.
  • Very High Efficiency and Fast response.
  • Low failure rate in all weather conditions (Indoor and Outdoor models)
  • Solid state Micro controlled circuit.
  • Rugged AC synchronous motor.
  • Precise electronic sensing for all trips.
  • Less active component avoids failure ratings.
  • Output regulation of 0.5% can be achieved
  • Zero Waveform Distortion
  • No effect of power factor.
  • Ruggedised construction, Excellent quality and high durability.
  • Suitable for unbalanced input voltage conditions and unbalanced load conditions
APPLICATIONS:
  • CNC Machines, Laser Machines and Molding Machines etc.
  • Refrigeration and Air-conditioning.
  • Laboratory equipment’s.
  • Office Automation.
  • Research Labs.
  • Domestic Purpose.
  • Computer and Micro-Processor Controlled Equipment’s.
  • Processors, Phototypesetters, Photographic Equipment’s.
  • Photo Copiers and Packaging Industries.
  • Medical Equipment’s, X-Ray Machines, E.C.G. Machines I Monitors, MRI, CT Scans Etc.
Technical Specification
MODEL AIR COOLED
PARAMETERS TECHNICAL DATA
Rating 1KVA-50KVA
INPUT VOLTAGE RANGE 125V-280V, 140V-270V, 170V-270V, (P-N) (customized Ranges shall be undertaken)
FREQUENCY 50Hz ± 5%
OUTPUT VOLTAGE 220V/230V/240V (or as per application can be set)
REGULATION ±1% Or 5% Or 10% (or as per application can be set)
FREQUENCY Same as Input
EFFICIANCY UPTO 98%
EFFECT OF LOAD POWER FACTOR NIL
EFFECT OF LOAD POWER FACTOR NIL
CORRECTION SPEED 35V/SEC (P-N)
INSULATION Class F
INDICATIONS/METERING (2x16 LCD DISPLY) Mains On, Output Ok, Input Voltage, Output Voltage, Output Current, Frequency, Low Cut-Off, High Cut-Off,
PROTECTION Input breaker, Output Relay/Contactor for High and Low Cut-Off, Fuse for Control Circuit, Manual Bypass Switch, Phase reversal protection and Overload Tripping.
Optional Features EMI/RF Filter/ Inbuilt Isolation Transformer (customized designs shall be undertaken)
OPRATING TEMPERATURE 0°C to 55°C,
HUMIDITY Up to 95% Non-Condensing
CABINET BOX CNC-IP 20, Optional Higher IP Offered